Netapp Fas3140 Manual
Nareboot - Stops and then restarts the node. Reboot -t minutes reboot -s reboot -r reboot -d dumpstring reboot -f reboot halts the node and then restarts it. Reboot is commonly used to allow modified configuration files to take effect or to run a newly installed version of Data ONTAP. NFS clients can maintain use of a file over a halt or reboot, although the node will fail to respond during that time. CIFS, FCP, and iSCSI clients cannot safely maintain use of a file over a halt or reboot. If the node is running CIFS, FCP or iSCSI, you may use the -t option to specify the time before shutdown. If reboot is invoked without -t, it displays the number of CIFS users, the number of open CIFS files, the number of mapped LUNs and the number of connected FCP and iSCSI clients.
Then it prompts you for the number of minutes to delay. Cifs terminate automatically notifies all CIFS clients that a CIFS shut-down is scheduled in mins minutes, and asks them to close their open files. CIFS files that are still open at the time the node reboots will lose writes that had been cached but not written. FCP and iSCSI will not notify clients, but will allow administrators to confirm that the mapped LUNs are not in use.

LUNs that are in use at the time the node reboots will result in client failures. Reboot logs a message in the /etc/messages file (see messages(5)) file to indicate that the node was rebooted on purpose.t minutes Reboots after the indicated number of minutes.
Applies only if the node is running CIFS, FCP, or iSCSI.s Initiates a clean system shutdown, followed by a power cycle reboot. (When the -s flag is omitted, reboot performs a clean shutdown but does not power cycle the appliance.). The reboot -s command is equivalent to physically turning the power to the head off and back on after typing 'halt'. The reboot -s command does not power cycle the appliance shelves.r Bypasses the shutdown process and initiates a power cycle reboot, without first performing a clean system shutdown. (When the -r flag is omitted, reboot performs a clean shutdown but does not power cycle the appliance.). The reboot -r command is equivalent to physically turning the power to the head off and back on, without first halting the system.
Use this command only when instructed to do so by technical support. The reboot -r command does not power cycle the appliance shelves.d dumpstring Dumps system core and reboots the node. This results in a dirty shutdown; cached data will not be flushed to disk. The dumpstring should indicate the reason for the core dump. Because it results in a dirty shutdown, the -d option generally should not be used for normal maintenance (see NOTES in ).f Applies only to nodes in a High Availability (HA) configuration. If you enter the reboot -f command on a node, its partner does not take over. You cannot use the reboot command in partner mode to reboot a failed node.
If you reboot the live node that has taken over the failed node, after the reboot, the live node reinitiates the takeover process.,.
30435 V3200 Series Model number View document Download documents V3270 format v3250 format V3240 format v3220 format V3210 format Document Description View/Print Order Part No. 215-12157B0 Describes how to install and maintain the 42U 1280mm system cabinet. 210-06755+B0 Instructions for using the system cabinet relocation kit for the 42U 1280mm system cabinet. 215-05266A0 Describes how to install and maintain the 42U system cabinet.
215-05677B0ur001 Describes the 42U system cabinet, deep associated FRUs, and provides maintenance and FRU replacement instructions. 215-11429A0ur004 Describes how to quickly upgrade controller hardware in a cluster by moving storage or moving volumes. 215-08510A0 Describes how to replace the illuminated badge on a 42U system cabinet, deep.
Netapp Fas3140 Service Manual
215-07732A0 Describes how to install the pass-through panel in system cabinets where power connectors are at the front of the chassis and power distribution units are located in the rear of the chassis. 210-06712+B0 Describes how to install the two-post rail fits for flush-mount and mid-mount FAS9000 and AFF A700 systems. 210-06672+A0 Describes how to install the SuperRail kit in system cabinets and 4-post Telco racks. 215-04574A0 Describes how to install or replace a 3-Phase PDU in a NetApp 42U system cabinet. 215-06774A0ur004 The Platform Monitoring Guide is no longer available. See the Hardware Universe for the data that was found in the Platform Monitoring Guide.
210-04607+B0 Describes how to install the Rail Kit II system cabinet rails in the 42U system cabinet Part No. 215-04940A0 Describes how to replace existing PDUs with a 30A, single-phase, 12-Outlet PDU.
Netapp Fas3140 Power Supply
210-06626+B0 Describes safety information and regulatory notices. 215-06458A0ur014 The Site Requirements Guide is no longer available. See the Hardware Universe for the data that was found in the Site Requirements Guide.
Support Matrix for all Storage Arrays attached to V-Series and gFiler Systems Part No. 210-05509+A0 Graphical instructions for the system cabinet relocating kit using the corrugated packaging and folding ramp. 210-05128+A0 Graphical instructions for the system cabinet relocating kit; the kit includes a new ramp to stabilize the pallet. 210-04874+B0 Graphical instructions for unpacking your system cabinet from the shipping crate.
210-00734+D0 Installation instructions for the NetApp Telco Tray and universal rail kit. 210-05208+A0 Graphical instructions for unpacking your system cabinet from the corrugated shipping container.
215-12065A0UR005 Provides information to upgrade controller hardware running ONTAP 9 using aggregate relocation.